Centro de Investigação
Permanent URI for this community
Browse
Browsing Centro de Investigação by Author "Aguiar Rosa, S"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- The Accuracy of PiCCO® in Measuring Cardiac Output in Patients Under Therapeutic Hypothermia: Comparison With Transthoracic EchocardiographyPublication . Souto Moura, T; Aguiar Rosa, S; Germano, N; Cavaco, R; Sequeira, T; Alves, M; Papoila, AL; Bento, LBackground: Invasive cardiac monitoring using thermodilution methods such as PiCCO® is widely used in critically ill patients and provides a wide range of hemodynamic variables, including cardiac output (CO). However, in post-cardiac arrest patients subjected to therapeutic hypothermia, the low body temperature possibly could interfere with the technique. Transthoracic Doppler echocardiography (ECHO) has long proved its accuracy in estimating CO, and is not influenced by temperature changes. Objective: To assess the accuracy of PiCCO® in measuring CO in patients under therapeutic hypothermia, compared with ECHO. Design and patients: Thirty paired COECHO/COPiCCO measurements were analyzed in 15 patients subjected to hypothermia after cardiac arrest. Eighteen paired measurements were obtained at under 36°C and 12 at ≥36°C. A value of 0.5l/min was considered the maximum accepted difference between the COECHO and COPiCCO values. Results: Under conditions of normothermia (≥36°C), the mean difference between COECHO and COPiCCO was 0.030 l/min, with limits of agreement (-0.22, 0.28) - all of the measurements differing by less than 0.5 l/min. In situations of hypothermia (<36°C), the mean difference in CO measurements was -0.426 l/min, with limits of agreement (-1.60, 0.75), and only 44% (8/18) of the paired measurements fell within the interval (-0.5, 0.5). The calculated temperature cut-off point maximizing specificity was 35.95°C: above this temperature, specificity was 100%, with a false-positive rate of 0%. Conclusions: The results clearly show clinically relevant discordance between COECHO and COPiCCO at temperatures of <36°C, demonstrating the inaccuracy of PiCCO® for cardiac output measurements in hypothermic patients.
- The Impact of Ischemia Assessed by Magnetic Resonance on Functional, Arrhythmic, and Imaging Features of Hypertrophic CardiomyopathyPublication . Aguiar Rosa, S; Thomas, B; Fiarresga, A; Papoila, AL; Alves, M; Pereira, R; Branco, G; Cruz, I; Rio, P; Baquero, L; Cruz Ferreira, R; Mota Carmo, M; Rocha Lopes, LAims: The aim of the study is to investigate the association between the degree of ischemia due to coronary microvascular dysfunction (CMD) and the left ventricular (LV) tissue characteristics, systolic performance, and clinical manifestations in hypertrophic cardiomyopathy (HCM). Methods and Results: This prospective study enrolled 75 patients with HCM without obstructive epicardial coronary artery disease. Each patient underwent cardiovascular magnetic resonance (CMR) including parametric mapping, perfusion imaging during regadenoson-induced hyperemia, late gadolinium enhancement (LGE) and three-dimensional longitudinal, circumferential, and radial strains analysis. Electrocardiogram, 24-h Holter recording, and cardiopulmonary exercise testing (CPET) were performed to assess arrhythmias and functional capacity. In total, 47 (63%) patients were men with the mean age of 54.6 (14.8) years, 51 (68%) patients had non-obstructive HCM, maximum wall thickness (MWT) was 20.2 (4.6) mm, LV ejection fraction (LVEF) was 71.6 (8.3%), and ischemic burden was 22.5 (16.9%) of LV. Greater MWT was associated with the severity of ischemia (β-estimate:1.353, 95% CI:0.182; 2.523, p = 0.024). Ischemic burden was strongly associated with higher values of native T1 (β-estimate:9.018, 95% CI:4.721; 13.315, p < 0.001). The association between ischemia and LGE was significant in following subgroup analyses: MWT 15-20 mm (β-estimate:1.941, 95% CI:0.738; 3.143, p = 0.002), non-obstructive HCM (β-estimate:1.471, 95% CI:0.258; 2.683, p = 0.019), women (β-estimate:1.957, 95% CI:0.423; 3.492, p = 0.015) and age <40 years (β-estimate:4.874, 95% CI:1.155; 8.594, p = 0.016). Ischemia in ≥21% of LV was associated with LGE >15% (AUC 0.766, sensitivity 0.724, specificity 0.659). Ischemia was also associated with atrial fibrillation or flutter (AF/AFL) (OR-estimate:1.481, 95% CI:1.020; 2.152, p = 0.039), but no association was seen for non-sustained ventricular tachycardia. Ischemia was associated with shorter time to anaerobic threshold (β-estimate: -0.442, 95% CI: -0.860; -0.023, p = 0.039). Conclusion: In HCM, ischemia associates with morphological markers of severity of disease, fibrosis, arrhythmia, and functional capacity.