- Cardiac Resynchronization System Implantation Guided by Three-Dimensional Electroanatomic MappingPublication . Cunha, PS; Santos, H; Oliveira, MM
- Complete Atrioventricular Block in Acute Coronary Syndrome: Prevalence, Characterisation and Implication on OutcomePublication . Aguiar Rosa, S; Timóteo, AT; Ferreira, L; Carvalho, R; Oliveira, MM; Cunha, PS; Viveiros Monteiro, A; Portugal, G; Almeida Morais, L; Daniel, P; Cruz Ferreira, RPURPOSE: The aim was to characterise acute coronary syndrome patients with complete atrioventricular block and to assess the effect on outcome. METHODS: Patients admitted with acute coronary syndrome were divided according to the presence of complete atrioventricular block: group 1, with complete atrioventricular block; group 2, without complete atrioventricular block. Clinical, electrocardiographic and echocardiographic characteristics and prognosis during one year follow-up were compared between the groups. RESULTS: Among 4799 acute coronary syndrome patients admitted during the study period, 91 (1.9%) presented with complete atrioventricular block. At presentation, group 1 patients presented with lower systolic blood pressure, higher Killip class and incidence of syncope. In group 1, 86.8% presented with ST-segment elevation myocardial infarction (STEMI), and inferior STEMI was verified in 79.1% of patients in group 1 compared with 21.9% in group 2 ( P<0.001). Right ventricular myocardial infarction was more frequent in group 1 (3.3% vs. 0.2%; P<0.001). Among patients who underwent fibrinolysis complete atrioventricular block was observed in 7.3% in contrast to 2.5% in patients submitted to primary percutaneous coronary intervention ( P<0.001). During hospitalisation group 1 had worse outcomes, with a higher incidence of cardiogenic shock (33.0% vs. 4.5%; P<0.001), ventricular arrhythmias (17.6% vs. 3.6%; P<0.001) and the need for invasive mechanical ventilation (25.3% vs. 5.1%; P<0.001). After a propensity score analysis, in a multivariate regression model, complete atrioventricular block was an independent predictor of hospital mortality (odds ratio 3.671; P=0.045). There was no significant difference in mortality at one-year follow-up between the study groups. CONCLUSION: Complete atrioventricular block conferred a worse outcome during hospitalisation, including a higher incidence of cardiogenic shock, ventricular arrhythmias and death.
- Does Permanent Atrial Fibrillation Modify Response to Cardiac Resynchronization Therapy in Heart Failure Patients?Publication . Abreu, A; Oliveira, MM; Cunha, PS; Santa Clara, H; Portugal, G; Rodrigues, I; Santos, V; Almeida-Morais, L; Selas, M; Soares, R; Branco, LM; Cruz Ferreira, R; Mota Carmo, MINTRODUCTION: The benefits of cardiac resynchronization therapy (CRT) documented in heart failure (HF) may be influenced by atrial fibrillation (AF). We aimed to compare CRT response in patients in AF and in sinus rhythm (SR). METHODS: We prospectively studied 101 HF patients treated by CRT. Rates of clinical, echocardiographic and functional response, baseline NYHA class and variation, left ventricular ejection fraction, volumes and mass, atrial volumes, cardiopulmonary exercise test (CPET) duration (CPET dur), peak oxygen consumption (VO2max) and ventilatory efficiency (VE/VCO2 slope) were compared between AF and SR patients, before and at three and six months after implantation of a CRT device. RESULTS: All patients achieved ≥95% biventricular pacing, and 5.7% underwent atrioventricular junction ablation. Patients were divided into AF (n=35) and SR (n=66) groups; AF patients were older, with larger atrial volumes and lower CPET dur and VO2max before CRT. The percentages of clinical and echocardiographic responders were similar in the two groups, but there were more functional responders in the AF group (71% vs. 39% in SR patients; p=0.012). In SR patients, left atrial volume and left ventricular mass were significantly reduced (p=0.015 and p=0.021, respectively), whereas in AF patients, CPET dur (p=0.003) and VO2max (p=0.001; 0.083 age-adjusted) showed larger increases. CONCLUSION: Clinical and echocardiographic response rates were similar in SR and AF patients, with a better functional response in AF. Improvement in left ventricular function and volumes occurred in both groups, but left ventricular mass reduction and left atrial reverse remodeling were seen exclusively in SR patients
- Impact of Substrate-Based Ablation for Ventricular Tachycardia in Patients with Frequent Appropriate Implantable Cardioverter-Defibrillator Therapy and Dilated Cardiomyopathy: Long-Term Experience with High-Density MappingPublication . Oliveira, MM; Cunha, PS; Valente, B; Portugal, G; Lousinha, A; Pereira, M; Braz, M; Delgado, A; Cruz Ferreira, RIntroduction: Recurrent ventricular tachycardia (VT) episodes have a negative impact on the clinical outcome of implantable cardioverter-defibrillator (ICD) patients. Modification of the arrhythmogenic substrate has been used as a promising approach for treating recurrent VTs. However, there are limited data on long-term follow-up. Aim: To analyze long-term results of VT substrate-based ablation using high-density mapping in patients with severe left ventricular (LV) dysfunction and recurrent appropriate ICD therapy. Methods: We analyzed 20 patients (15 men, 55% with non-ischemic cardiomyopathy, age 58±15 years, LV ejection fraction 32±5%) and repeated appropriate shocks or arrhythmic storm (>2 shocks/24 h) despite antiarrhythmic drug therapy and optimal heart failure medication. All patients underwent ventricular programmed stimulation (600 ms/S3) to document VT. A sinus rhythm (SR) voltage map was created with a three-dimensional electroanatomic mapping system (CARTO, Biosense Webster, CA) using a PentaRay® high-density mapping catheter (Biosense Webster, CA) to delineate areas of scarred myocardium (ventricular bipolar voltage ≤0.5 mV --- dense scar; 0.5-1.5 mV --- border zone; ≥1.5 mV --- healthy tissue) and to provide high-resolution electrophysiological mapping. Substrate modification included elimination of local abnormal ventricular activities (LAVAs) during SR (fractionated, split, low-amplitude/long-lasting, late potentials, pre-systolic), and linear ablation to obtain scar homogenization and dechanneling. Pace-mapping techniques were used when capture was possible. The LV approach was retrograde in nine cases, transseptal in five and epi-endocardial in four. In two patients ablation was performed inside the right ventricle. Results: LAVAs and scar areas were modified in all patients. Mean procedure duration was 149 min (105-220 min), with radiofrequency ranging from 18 to 70 min (mean 33 min) and mean fluoroscopy time of 15 min. Non-inducibility was achieved in 75% of cases (in four patients with hemodynamic deterioration and an LV assist device, VT inducibility was not performed). There were two cases of pericardial tamponade, drained successfully. During a follow-up of 50±24 months, 65% had no VT recurrences. Among the seven patients with recurrences, three underwent redo ablation and four, with fewer VT episodes, received appropriate ICD therapy. There were five hospital readmissions due to heart failure decompensation, one patient died in the first week after unsuccessful ablation of a VT storm and three died (stroke and pneumonia) >1 year after ablation. Conclusion: Catheter ablation based on substrate modification is feasible and safe in patients with frequent VTs and severe LV dysfunction. This approach may be of clinical relevance, with potential long-term benefits in reducing VT burden.
- Influence of Remote Monitoring on Long-Term Cardiovascular Outcomes after Cardioverter-Defibrillator ImplantationPublication . Portugal, G; Cunha, PS; Valente, B; Feliciano, J; Lousinha, A; Alves, S; Braz, M; Pimenta, R; Delgado, AS; Oliveira, MM; Cruz Ferreira, RAIMS: Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). METHODS: We performed a retrospective cohort study of consecutive patients who underwent ICD implantation for primary prevention. RM was initiated with patient consent according to availability of RM hardware at implantation. Patients with concomitant cardiac resynchronization therapy were excluded. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. A Cox proportional hazards model was employed to estimate the effect of RM on mortality and a composite endpoint of cardiovascular mortality and hospital admission due to heart failure (HF). RESULTS: 312 patients were included with a median follow-up of 37.7months (range 1 to 146). 121 patients (38.2%) were under RM since the first outpatient visit post-ICD and 191 were in conventional follow-up. No differences were found regarding age, left ventricular ejection fraction, heart failure etiology or NYHA class at implantation. Patients under RM had higher long-term survival (hazard ratio [HR] 0.50, CI 0.27-0.93, p=0.029) and lower incidence of the composite outcome (HR 0.47, CI 0.27-0.82, p=0.008). After multivariate survival analysis, overall survival was independently associated with younger age, higher LVEF, NYHA class lower than 3 and RM. CONCLUSION: RM was independently associated with increased long-term survival and a lower incidence of a composite endpoint of hospitalization for HF or cardiovascular mortality.
- Left Atrial Appendage Volume As a New Predictor of Atrial Fibrillation Recurrence After Catheter AblationPublication . Teixeira, P; Oliveira, MM; Ramos, R; Rio, P; Cunha, PS; Delgado, AS; Pimenta, R; Cruz Ferreira, RPURPOSE: Recurrence of atrial fibrillation (AF) after catheter ablation is common, being clinically relevant to identify predictors of recurrence. The left atrial appendage (LAA) role as an AF trigger is scarcely explored. Our aim was to identify if LAA volume is an independent predictor of AF recurrence after catheter ablation. METHODS: We analysed 52 patients (aged 54 ± 10 years, 58% male) with paroxysmal and persistent AF who underwent a first AF catheter ablation and had performed contrast-enhanced cardiac computed tomography (CT) prior to the procedure. RESULTS: The mean left atrial and LAA volumes measured by cardiac CT were 98.9 ± 31.8 and 9.3 ± 3.5 mL, respectively. All patients received successful pulmonary vein isolation and were followed up for 24 months. AF recurrence occurred in 17 patients (33%). LAA volume was significantly greater in patients with AF recurrence than in those without recurrence (11.3 ± 2.9 vs. 8.2 ± 3.4 mL; p = 0.002). Multivariable analysis using Cox regression revealed that LAA volume (hazard ratio 1.32; 95% confidence interval 1.12-1.55; p = 0.001) and persistent AF (hazard ratio 4.22; 95% confidence interval 1.48-12.07; p = 0.007) were independent predictors for AF recurrence. An LAA volume greater than 8.825 mL predicted AF recurrence with 94% sensitivity and 66% specificity. The Kaplan-Meier analysis showed a lower rate free from AF recurrence in the group with an LAA volume >8.825 mL (p < 0.001). CONCLUSIONS: Larger LAA volume was associated with AF recurrence after catheter ablation in patients with paroxysmal and persistent AF.
- A Link to Better Care: The Effect of Remote Monitoring on Long-Term Adverse Cardiac Events in a Propensity Score-Matched CohortPublication . Portugal, G; Cunha, PS; Valente, B; Feliciano, J; Lousinha, A; Alves, S; Braz, M; Pimenta, R; Delgado, AS; Oliveira, MM; Cruz Ferreira, RAIMS: There are conflicting data regarding the clinical benefits of device-based remote monitoring (RM). We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICDs). METHODS: We assessed the incidence of adverse cardiac events, overall mortality and device therapy efficacy and safety in a propensity score-matched cohort of patients under RM compared to patients under conventional follow-up. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. The primary outcome was time to a composite outcome of first hospital admission for heart failure or cardiovascular death. RESULTS: Of a total of 923 implantable device recipients, 164 matched patients were identified (84 under RM, 84 under conventional follow-up). The mean follow-up was 44 months (range 1-123). There were no significant differences regarding baseline characteristics in the matched cohorts. Patients under RM had a significantly lower incidence of the primary outcome (hazard ratio [HR] 0.42, confidence interval [CI] 0.20-0.88, p=0.022); there was a non-significant trend towards lower overall mortality (HR 0.53, CI 0.27-1.04, p=0.066). No significant differences between cohorts were found regarding appropriate therapies (RM vs. conventional follow-up, 8.1 vs. 8.2%, p=NS) or inappropriate therapies (6.8 vs. 5.0%, p=NS). CONCLUSION: In a propensity score-matched cohort of ICD recipients with long-term follow-up, RM was associated with a lower rate of a combined endpoint of hospital admission for heart failure or cardiovascular death.
- Looking at Late Repolarization to See Early DiseasePublication . Cunha, PS
- PentaRay Catheter in Persistent Atrial Fibrillation AblationPublication . Teixeira, P; Cunha, PS; Delgado, AS; Pimenta, R; Oliveira, MM; Cruz Ferreira, R
- Predictors of Response to Cardiac Resynchronization Therapy: A Prospective Cohort StudyPublication . Abreu, A; Oliveira, MM; Cunha, PS; Santa Clara, H; Santos, V; Portugal, G; Rio, P; Soares, R; Branco, LM; Alves, M; Papoila, AL; Cruz Ferreira, R; Mota Carmo, MINTRODUCTION: Cardiac resynchronization therapy (CRT) has modified the prognosis of chronic heart failure (HF) with left ventricular systolic dysfunction. However, 30% of patients do not have a favorable response. The big question is how to determine predictors of response. AIMS: To identify baseline characteristics that might influence echocardiographic response to CRT. METHODS AND RESULTS: We performed a prospective single-center hospital-based cohort study of consecutive HF patients selected to CRT (NYHA class II-IV, left ventricular ejection fraction (LVEF) <35% and QRS complex ≥120 ms). Responders were defined as those with a ≥5% absolute increase in LVEF at six months. Clinical, electrocardiographic, laboratory, echocardiographic, autonomic, endothelial and cardiopulmonary function parameters were assessed before CRT device implantation. Logistic regression models were used. Seventy-nine patients were included, 54 male (68.4%), age 68.1 years (standard deviation 10.2), 19 with ischemic etiology (24%). At six months, 51 patients (64.6%) were considered responders. Although by univariate analysis baseline tricuspid annular plane systolic excursion (TAPSE) and serum creatinine were significantly different in responders, on multivariate analysis only TAPSE was independently associated with response, with higher values predicting a positive response to CRT (OR=1.13; 95% CI: 1.02-1.26; p=0.020). TAPSE ≥15 mm was strongly associated with response, and TAPSE <15 mm with non-response (p=0.005). Responders had no TAPSE values below 10 mm. CONCLUSION: From a range of clinical and technical baseline characteristics, multivariate analysis only identified TAPSE as an independent predictor of CRT response, with TAPSE <15 mm associated with non-response. This study highlights the importance of right ventricular dysfunction in CRT response.