Browsing by Author "Goyri-O'Neill, J"
Now showing 1 - 10 of 15
Results Per Page
Sort Options
- BD-2 and BD-3 Increase Skin Flap Survival in a Model of Ischemia and Pseudomonas Aeruginosa InfectionPublication . Casal, D; Iria, I; Ramalho, JS; Alves, S; Mota-Silva, E; Mascarenhas-Lemos, L; Pontinha, C; Guadalupe-Cabral, M; Ferreira-Silva, J; Ferraz-Oliveira, M; Vassilenko, V; Goyri-O'Neill, J; Pais, D; Videira, PThe main aim of this work was to study the usefulness of human β-defensins 2 (BD-2) and 3 (BD-3), which are part of the innate immune system, in the treatment of infected ischemic skin flaps. We investigated the effect of transducing rat ischemic skin flaps with lentiviral vectors encoding human BD-2, BD-3, or both BD-2 and BD-3, to increase flap survival in the context of a P. aeruginosa infection associated with a foreign body. The secondary endpoints assessed were: bacterial counts, and biofilm formation on the surface of the foreign body. A local ischemic environment was created by producing arterialized venous flaps in the left epigastric region of rats. Flaps were intentionally infected by placing underneath them two catheters with 105 CFU of P. aeruginosa before the surgical wounds were hermetically closed. Flap biopsies were performed 3 and 7 days post-operatively, and the specimens submitted to immunohistochemical analysis for BD-2 and BD-3, as well as to bacterial quantification. Subsequently, the catheter segments were analyzed with scanning electron microscopy (SEM). Flaps transduced with BD-2 and BD-3 showed expression of these defensins and presented increased flap survival. Rats transduced with BD-3 presented a net reduction in the number of P. aeruginosa on the surface of the foreign body and lesser biofilm formation.
- Blood Supply to the Integument of the Abdomen of the Rat: A Surgical PerspectivePublication . Casal, D; Pais, D; Iria, I; Videira, P; Mota-Silva, E; Alves, S; Mascarenhas-Lemos, L; Pen, C; Vassilenko, V; Goyri-O'Neill, JBACKGROUND: Many fundamental questions regarding the blood supply to the integument of the rat remain to be clarified, namely the degree of homology between rat and humans. The aim of this work was to characterize in detail the macro and microvascular blood supply to the integument covering the ventrolateral aspect of the abdominal wall of the rat. METHODS: Two hundred five Wistar male rats weighing 250-350 g were used. They were submitted to gross anatomical dissection after intravascular colored latex injection (n = 30); conversion in modified Spalteholz cleared specimens (n=10); intravascular injection of a Perspex solution, and then corroded, in order to produce vascular corrosion casts of the vessels in the region (n = 5); histological studies (n = 20); scanning electron microscopy of vascular corrosion casts (n = 10); surgical dissection of the superficial caudal epigastric vessels (n = 100); and to thermographic evaluation (n = 30). RESULTS: The ventrolateral abdominal wall presented a dominant superficial vascular system, which was composed mainly of branches from the superficial caudal epigastric artery and vein in the caudal half. The cranial half still received significant arterial contributions from the lateral thoracic artery in all cases and from large perforators coming from the intercostal arteries and from the deep cranial epigastric artery. CONCLUSIONS: These data show that rats and humans present a great deal of homology regarding the blood supply to the ventrolateral aspect of the abdominal integument. However, there are also significant differences that must be taken into consideration when performing and interpreting experimental procedures in rats.
- Brachial Plexus Morphology and Vascular Supply in the Wistar RatPublication . Almeida, MA; Casal, D; Mafra, M; Mascarenhas-Lemos, L; Martins-Ferreira, J; Ferraz-Oliveira, M; Amarante, J; Goyri-O'Neill, JIntroduction: The rat is probably the animal species most widely used in experimental studies on nerve repair. The aim of this work was to contribute to a better understanding of the morphology and blood supply of the rat brachial plexus. Material and Methods: Thirty adult rats were studied regarding brachial plexus morphology and blood supply. Intravascular injection and dissection under an operating microscope, as well as light microscopy and scanning electron microscopy techniques were used to define the microanatomy of the rat brachial plexus and its vessels. Results: The rat brachial plexus was slightly different from the human brachial plexus. The arterial and venous supply to the brachial plexus plexus was derived directly or indirectly from neighboring vessels. These vessels formed dense and interconnected plexuses in the epineurium, perineurium, and endoneurium. Several brachial plexus components were accompanied for a relatively long portion of their length by large and constant blood vessels that supplied their epineural plexus, making it possible to raise these nerves as flaps. Discussion: The blood supply to the rat brachial plexus is not very different from that reported in humans, making the rat a useful animal model for the experimental study of peripheral nerve pathophysiology and treatment. Conclusion: Our results support the homology between the rat and the human brachial plexus in terms of morphology and blood supply. This work suggests that several components of the rat brachial plexus can be used as nerve flaps, including predominantly motor, sensory or mixed nerve fibers. This information may facilitate new experimental procedures in this animal model.
- Métrica Vertebral: a Aplicação de uma Nova Tecnologia na Análise da Coluna VertebralPublication . Quaresma, C; Dias, I; Forjaz Secca, M; Goyri-O'Neill, J; Branco, JObjectivo: Apresentar os resultados da primeira aplicação da nova tecnologia – Métrica Vertebral – na análise da posição 3D do vértice de cada uma das apófises espinhosas, em mulheres grávidas. Material e Métodos: O Métrica Vertebral foi aplicado a mulheres, sem patologia associada, em quatro momentos da gravidez (12, 20, 32, 37 semanas de gestação). Aplicaram-se modelos lineares univariados. Resultados: Observou-se que as diferenças que ocorrem ao longo da gravidez são mais significativas ao nível da posição y (anteroposterior). Verificou-se, igualmente, que existe uma correlação biomecânica positiva entre a posição do vértice de cada uma das vértebras com a posição homóloga das restantes. Discussão/Conclusão: Através do Métrica Vertebral foi possível obter resultados inovadores na análise biomecânica da coluna vertebral. É um dispositivo que tem diferentes aplicações podendo ser facilmente adoptado em áreas como ortopedia, neurocirurgia, pediatria e reabilitação. É de realçar ainda que este instrumento não se esgota na amostra da presente investigação pois pode ser futuramente aplicada à população em geral.
- Morphometric Analysis of the Extensor Tendons of the Hallux and Potential Implications for Tendon GraftingPublication . Casal, D; Pais, D; Almeida, MA; Bilhim, T; Santos, A; Goyri-O'Neill, JAlthough several tendon sources are available for reconstructive surgical procedures, all have one or more shortcomings. The aim of this work was to evaluate if the extensor tendons of the hallux showed anatomical characteristics that could make them an additional source for tendon grafting procedures.The authors performed a detailed morphometric analysis of the extensor tendons of the hallux in 26 lower limbs in order to evaluate the putative association of anatomical variants with hallux valgus, and to attempt to assess the feasibility of using part of the extensor apparatus of the hallux as a source of tendon for grafting procedures.An accessory extensor hallucis longus ten-don was found in 92.3% of cases. The extensor hallucis brevis tendon length was 10.5 ± 0.6 cm; its width was 0.5 ± 0.1 cm, and its thickness varied between 1-2 mm, making it a potentially good candidate as a source of ten-don grafts. Several anatomical variations were observed, namely the fusion of the tendons of the extensor hallucis brevis and the accessory extensor hallucis longus muscles in the distal part of the foot.This new therapeutic option, if implemented, would possibly increase the supply of autogenous donor tissue for reconstructive procedures, thereby enhancing the reconstructive surgeon’s armamentarium.
- Outcomes and Satisfaction of Two Optional Cadaveric Dissection Courses: a 3-Year Prospective StudyPublication . Pais, D; Casal, D; Mascarenhas-Lemos, L; Barata, P; Moxham, B; Goyri-O'Neill, JTeaching time dedicated to anatomy education has been reduced at many medical schools around the world, including Nova Medical School in Lisbon, Portugal. In order to minimize the effects of this reduction, the authors introduced two optional, semester-long cadaveric dissection courses for the first two years of the medical school curriculum. These courses were named Regional Anatomy I (RAI) and Regional Anatomy II (RAII). In RAI, students focus on dissecting the thorax, abdomen, pelvis, and perineum. In RAII, the focus shifts to the head, neck, back, and upper and lower limbs. This study prospectively analyzes students' academic achievement and perceptions within the context of these two, newly-introduced, cadaveric dissection courses. Students' satisfaction was assessed anonymously through a questionnaire that included items regarding students' perception of the usefulness of the courses for undergraduate teaching, as well as with regards to future professional activity. For each of the three academic years studied, the final score (1 to 20) in General Anatomy (GA), RAI, and RAII was on average 14.26 ± 1.89; 16.94 ± 1.02; 17.49 ± 1.01, respectively. The mean results were lower in GA than RAI or RAII (P < 0.001). Furthermore, students who undertook these courses ranked them highly with regards to consolidating their knowledge of anatomy, preparing for other undergraduate courses, and training for future clinical practice. These survey data, combined with data on participating students' academic achievement, lend strong support to the adoption of similar courses as complementary and compulsory disciplines in a modern medical curriculum.
- Prostatic Arterial Supply: Anatomic and Imaging Findings Relevant for Selective Arterial EmbolizationPublication . Bilhim, T; Pisco, JM; Rio Tinto, H; Fernandes, L; Pinheiro, LC; Furtado, A; Casal, D; Duarte, M; Pereira, J; Oliveira, A; Goyri-O'Neill, JPURPOSE: To describe the anatomy and imaging findings of the prostatic arteries (PAs) on multirow-detector pelvic computed tomographic (CT) angiography and digital subtraction angiography (DSA) before embolization for symptomatic benign prostatic hyperplasia (BPH). MATERIALS AND METHODS: In a retrospective study from May 2010 to June 2011, 75 men (150 pelvic sides) underwent pelvic CT angiography and selective pelvic DSA before PA embolization for BPH. Each pelvic side was evaluated regarding the number of independent PAs and their origin, trajectory, termination, and anastomoses with adjacent arteries. RESULTS: A total of 57% of pelvic sides (n = 86) had only one PA, and 43% (n = 64) had two independent PAs identified (mean PA diameter, 1.6 mm ± 0.3). PAs originated from the internal pudendal artery in 34.1% of pelvic sides (n = 73), from a common trunk with the superior vesical artery in 20.1% (n = 43), from the anterior common gluteal-pudendal trunk in 17.8% (n = 38), from the obturator artery in 12.6% (n = 27), and from a common trunk with rectal branches in 8.4% (n = 18). In 57% of pelvic sides (n = 86), anastomoses to adjacent arteries were documented. There were 30 pelvic sides (20%) with accessory pudendal arteries in close relationship with the PAs. No correlations were found between PA diameter and patient age, prostate volume, or prostate-specific antigen values on multivariate analysis with logistic regression. CONCLUSIONS: PAs have highly variable origins between the left and right sides and between patients, and most frequently arise from the internal pudendal artery.
- A Rare Variant of the Ulnar Artery with Important Clinical Implications: a Case ReportPublication . Casal, D; Pais, D; Toscano, T; Bilhim, T; Rodrigues, L; Figueiredo, I; Aradio, S; Almeida, MA; Goyri-O'Neill, JBACKGROUND: Variations in the major arteries of the upper limb are estimated to be present in up to one fifth of people, and may have significant clinical implications. CASE PRESENTATION: During routine cadaveric dissection of a 69-year-old fresh female cadaver, a superficial brachioulnar artery with an aberrant path was found bilaterally. The superficial brachioulnar artery originated at midarm level from the brachial artery, pierced the brachial fascia immediately proximal to the elbow, crossed superficial to the muscles that originated from the medial epicondyle, and ran over the pronator teres muscle in a doubling of the antebrachial fascia. It then dipped into the forearm fascia, in the gap between the flexor carpi radialis and the palmaris longus. Subsequently, it ran deep to the palmaris longus muscle belly, and superficially to the flexor digitorum superficialis muscle, reaching the gap between the latter and the flexor carpi ulnaris muscle, where it assumed is usual position lateral to the ulnar nerve. CONCLUSION: As far as the authors could determine, this variant of the superficial brachioulnar artery has only been described twice before in the literature. The existence of such a variant is of particular clinical significance, as these arteries are more susceptible to trauma, and can be easily confused with superficial veins during medical and surgical procedures, potentially leading to iatrogenic distal limb ischemia.
- A Rare Variation of the Extensor Indicis Proprius Tendon With Important Clinical ImplicationsPublication . Casal, D; Pais, D; Bilhim, T; Ribeiro, V; Cunha, S; Damásio, C; Fernandes, R; Almeida, MA; Goyri-O'Neill, JIntroduction: Anatomical variations of the extensor tendons to the fingers are of great clinical interest, due to the relatively high frequency of tendon injury in clinical practice. Material and methods: During routine dissection of the right upper limb of a 67-year-old female preserved corpse, the extensor indicis proprius (EIP) muscle belly originated 3 independent tendons, each with a separate fascial sheath, forming a triple EIP tendon. There was a larger tendon, which occupied a central position, that represented the usual single EIP tendon. In addition, there were two thinner radial and ulnar accessory EIP tendons. The radial-EIP tendon crossed deep to the extensor digitorum communis (EDC) tendon to the index finger in the distal half of the dorsum of the hand to reach the radial side of the extensor expansion hood of the index finger. Discussion: According to the literature, the frequency of a triple EIP tendon ranges from 0%, to as high as 7%, although most authors do not acknowledge the presence of this variant in their series. This variant of the EIP tendon, in which the radial-EIP terminated laterally to the termination of the tendon of the EDC to the index finger, may be a source of confusion intraoperatively, as the EIP tendon has traditionally been identified on the basis of its ulnar location with respect to the EDC tendon. Conclusion: The possibility of a triple EIP tendon should certainly be born in mind by all surgeons when performing tendon repairs, tenoplasties or tendon transfers.
- Reconstruction of a Long Defect of the Ulnar Artery and Nerve with an Arterialized Neurovenous Free Flap in a Teenager: A Case Report and Literature ReviewPublication . Casal, D; Pais, D; Mota-Silva, E; Pelliccia, G; Iria, I; Videira, P; Mendes, MM; Goyri-O'Neill, J; Mouzinho, MMThere is evidence that nerve flaps are superior to nerve grafts for bridging long nerve defects. Moreover, arterialized neurovenous flaps (ANVFs) have multiple potential advantages over traditional nerve flaps in this context. This paper describes a case of reconstruction of a long defect of the ulnar artery and nerve with an arterialized neurovenous free flap and presents a literature review on this subject. A 16-year-old boy sustained a stab wound injury to the medial aspect of the distal third of his right forearm. The patient was initially observed and treated at another institution where the patient was diagnosed with a flexor carpis ulnaris muscle and an ulnar artery section. The artery was ligated and the muscle was sutured. Four months later, the patient was referred to our institution with complaints of ulnar nerve damage, as well as hand pain and cold intolerance. Physical examination and ancillary tests supported the diagnosis of ulnar artery and nerve complete section. Surgery revealed an 8 cm hiatus of the ulnar artery and a 5 cm defect of the ulnar nerve. These gaps were bridged with a flow through ANVF containing the sural nerve and the lesser saphenous vein. The postoperative course was uneventful. Two years postoperatively, the patient had regained normal trophism and M5 strength in all previously paralyzed muscles according to the Medical Research Council Scale. Thermography revealed good perfusion in the right ulnar angiosome. The ANVF may be an expedite, safe and efficient option to reconstruct a long ulnar nerve and artery defect.