Browsing by Author "Primo, J"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- Clinical Outcome of a Single Procedure Cryoballoon Ablation for the Treatment of Atrial Fibrillation: a Real-World Multicenter Experience in PortugalPublication . Silva Cunha, P; Fonseca, P; Laranjo, S; Montenegro Sá, F; Valente, B; Portugal, G; Gonçalves, H; Nogueira da Silva, M; Brandão, L; Oliveira, MM; Primo, JBackground: Cryoballoon ablation (CBA) for pulmonary vein isolation (PVI) has been growing as an alternative technique, not only in patients with paroxysmal atrial fibrillation (PAF) but also in persistent atrial fibrillation (AF). Cryoballoon ablation has demonstrated encouraging acute and mid-term results. However, data on long-term follow-up of CB-based PVI are scarce. Objective: We sought to examine efficacy, safety, and long-term outcomes of CBA in PAF and persistent AF in four Portuguese centers. Methods: All patients that were treated with the cryoballoon catheter according to routine practices with a second-generation 28-mm CB in four centers were included. This was a retrospective, non-randomized analysis. Patients were followed-up for >12 months and freedom from atrial arrhythmias (AA) was evaluated at the end of follow-up. Results: Four hundred and six patients (57.7±12.4 years, 66% men) participated. AF was paroxysmal in 326 patients (80.2%) and persistent in 80 (19.7%). The mean procedure time duration was 107.7±50.9 min, and the fluoroscopy time was 19.5±9.7 min. Procedural/periprocedural complications occurred in 30 cases (7.3%), being transient phrenic nerve palsy the most frequent incident (2 out of 3 complications). Anatomic variations of the PV were present in 16.1% of cases. At a mean follow-up of 22.0±15.0 months, 310 patients (76.3%) remained in stable sinus rhythm, with at least one AF episode recurrence documented in 98 cases (24.1%). The recurrence rate was 20.5% in the PAF group and 37.8% in the persistent AF group. Conclusion: In this multicenter experience, a single CBA procedure resulted in 75.9% freedom from AF at a 22-month follow-up. This technique was demonstrated to be a safe and effective option in experienced centers for the treatment of PAF and PersAF.
- Remote versus In-Office Monitoring for Implantable Cardioverter Defibrillators: Results from a Randomized Pragmatic Controlled Study in PortugalPublication . Martins Oliveira, M; Fernandes, M; Reis, H; Primo, J; Sanfins, V; Silva, V; Silva Cunha, P; Silva, M; Nicola, P; PORTLink Study InvestigatorsIntroduction: Remote monitoring (RM) is a safe and effective alternative to in-office conventional follow-up. Objective: We aimed to evaluate patient satisfaction with RM and its impact on healthcare resources in a population with cardiac implantable electronic devices. Methods: Randomized, pragmatic, open-label controlled trial, with adult wearers of implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy with ICD (CRT-D), eligible for the CareLink® system. Patients newly implanted or with previous conventional follow-up were randomized to RM or conventional follow-up (control), and followed for 12 months, according to the centers' practice. The number of in-office visits and adverse events were compared between groups. Patient and healthcare professionals' satisfaction with RM were described. Results: Of the 134 randomized patients (69 RM; 65 control, aged 60±13 years), 80% were male, 23% employed, 72% ICD wearers and 54% newly implanted. Most patients (70%) reported travel costs less than 15€/visit, and 46% daily routine interference with in-office visits. Median physician/technician time with patient was 15 min/15 min, per in-office visit. Excluding baseline and final visits, control patients had more in-office visits in total: median 1 vs. 0, p<0.001. In 81% of the in-office visits, no clinical measures were taken. There were 10 adverse events, with no differences between groups. At the final visit, 95% of RM patients considered RM easy/very easy to use, and would all prefer to maintain RM and recommend it to others. All professionals found the CareLink website easy/very easy to use and were satisfied with transmission data. Conclusions: In a Portuguese population with ICD and CRT-D, RM safely reduced the burden of in-office visits, with high levels of satisfaction among patients and healthcare professionals.