Publication
Lidocaine-Induced Central Nervous System Toxicity During Implantable Cardioverter Defibrillator Placement – A Case Report and Literature Review
dc.contributor.author | Nunes Silva, M | |
dc.contributor.author | Ferro, A | |
dc.contributor.author | Fragata, I | |
dc.date.accessioned | 2023-09-28T14:42:49Z | |
dc.date.available | 2023-09-28T14:42:49Z | |
dc.date.issued | 2023-05 | |
dc.description.abstract | Lidocaine, a local anesthetic, is commonly used in various medical procedures. Despite its widespread use, most physicians are not familiar with the life threatening presentation of lidocaine toxicity and its treatment. Our case demonstrates successful management of local lidocaine-induced systemic toxicity in a 53-year-old female during insertion of an implantable cardioverter defibrillator. Our goal was to raise awareness of the risks and symptoms of local anesthetic toxicity, educate regarding the site of administration and dose of anesthetic delivery as independent risk factors for systemic toxicity and highlight the use of intravenous lipid emulsion as an antidote. | pt_PT |
dc.description.abstract | A lidocaína é um anestético local vulgarmente usado em vários procedimentos médicos. Apesar do seu uso abrangente, a maioria dos clínicos não está familiarizada com os sinais e sintomas de toxicidade e o seu tratamento. O nosso caso demonstra o tratamento bem-sucedido de uma intoxicação sistémica de lidocaína numa mulher de 53 anos durante a implantação de um cardioversor desfibrilhador implantável (CDI). O nosso objetivo é consciencializar para os riscos, sinais e sintomas da intoxicação de anestésicos locais, informar sobre o local e dose de administração como fatores de risco independentes para a toxicidade sistémica e enfatizar ouso de emulsão lipídica como antídoto. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | Rev Port Cardiol . 2023 May;42(5):483.e1-483.e4. | pt_PT |
dc.identifier.doi | 10.1016/j.repc.2020.07.025 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.17/4698 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Elsevier España | pt_PT |
dc.subject | HSM ANS | pt_PT |
dc.subject | Humans | pt_PT |
dc.subject | Female | pt_PT |
dc.subject | Anesthetics, Local / adverse effects | pt_PT |
dc.subject | Middle Aged | pt_PT |
dc.subject | Central Nervous System | pt_PT |
dc.subject | Defibrillators, Implantable* / adverse effects | pt_PT |
dc.subject | Lidocaine* / adverse effects | pt_PT |
dc.subject | Risk Factors | pt_PT |
dc.title | Lidocaine-Induced Central Nervous System Toxicity During Implantable Cardioverter Defibrillator Placement – A Case Report and Literature Review | pt_PT |
dc.title.alternative | Intoxicação do Sistema Nervoso Central Durante a Implantação de um Cardioversor Desfibrilhador Implantável -- Um Caso Clínico e Revisão da Literatura | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 483.e4 | pt_PT |
oaire.citation.issue | 5 | pt_PT |
oaire.citation.startPage | 483.e1 | pt_PT |
oaire.citation.title | Revista Portuguesa de Cardiologia | pt_PT |
oaire.citation.volume | 42 | pt_PT |
rcaap.rights | openAccess | pt_PT |
rcaap.type | article | pt_PT |