Publication
EHRA Expert Consensus Statement and Practical Guide on Optimal Implantation Technique for Conventional Pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS)
dc.contributor.author | Burri, H | |
dc.contributor.author | Starck, C | |
dc.contributor.author | Auricchio, A | |
dc.contributor.author | Biffi, M | |
dc.contributor.author | Burri, M | |
dc.contributor.author | D’Avila, A | |
dc.contributor.author | Deharo, JC | |
dc.contributor.author | Glikson, M | |
dc.contributor.author | Israel, C | |
dc.contributor.author | Lau, CP | |
dc.contributor.author | Leclercq, C | |
dc.contributor.author | Love, C | |
dc.contributor.author | Nielsen, J | |
dc.contributor.author | Vernooy, K | |
dc.contributor.author | Dagres, N | |
dc.contributor.author | Boveda, S | |
dc.contributor.author | Butter, C | |
dc.contributor.author | Marijon, E | |
dc.contributor.author | Braunschweig, F | |
dc.contributor.author | Mairesse, G | |
dc.contributor.author | Gleva, M | |
dc.contributor.author | Defaye, P | |
dc.contributor.author | Zanon, F | |
dc.contributor.author | Lopez-Cabanillas, N | |
dc.contributor.author | Guerra, J | |
dc.contributor.author | Vassilikos, V | |
dc.contributor.author | Oliveira, M | |
dc.date.accessioned | 2024-01-11T15:44:07Z | |
dc.date.available | 2024-01-11T15:44:07Z | |
dc.date.issued | 2021-07 | |
dc.description.abstract | With the global increase in device implantations, there is a growing need to train physicians to implant pacemakers and implantable cardioverter-defibrillators. Although there are international recommendations for device indications and programming, there is no consensus to date regarding implantation technique. This document is founded on a systematic literature search and review, and on consensus from an international task force. It aims to fill the gap by setting standards for device implantation. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | Europace . 2021 Jul 18;23(7):983-1008. | pt_PT |
dc.identifier.doi | 10.1093/europace/euaa367 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.17/4787 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Oxford | pt_PT |
dc.subject | HSM CAR | pt_PT |
dc.subject | Humans | pt_PT |
dc.subject | Consensus | pt_PT |
dc.subject | Asia | pt_PT |
dc.subject | Defibrillators, Implantable* | pt_PT |
dc.subject | Pacemaker, Artificial* | pt_PT |
dc.subject | United States | pt_PT |
dc.title | EHRA Expert Consensus Statement and Practical Guide on Optimal Implantation Technique for Conventional Pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS) | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 1008 | pt_PT |
oaire.citation.issue | 7 | pt_PT |
oaire.citation.startPage | 983 | pt_PT |
oaire.citation.title | EP Europace | pt_PT |
oaire.citation.volume | 23 | pt_PT |
rcaap.rights | openAccess | pt_PT |
rcaap.type | article | pt_PT |